News
Products
Documentation
Software
Service
Company
Training
Linear Encoders
Angle Encoders
Rotary Encoders
Length Gauges
CNC Controls
Subsequent Electronics
Touch Probes
Grid Encoders
News
Products
Linear Encoders
Sealed Linear Encoders
Exposed Linear Encoders
Selection guide for LIC
Selection guide for LIP
Selection guide for LIF
Selection guide for LIDA
Selection guide for PP
Selection guide LIP/LIF/LIC (vacuum)
LIP 481V / LIP 481U
LIF 471V / LIF 481V
LIC 4113V / LIC 4193V
Angle Encoders
Rotary Encoders
Length Gauges
CNC Controls
Subsequent Electronics
Touch Probes
Grid Encoders
Documentation
Software
Service
Company
Training
Home
Products
Linear Encoders
Exposed Linear Encoders
Selection guide LIP/LIF/LIC (vacuum)
Sealed Linear Encoders
Exposed Linear Encoders
Selection guide for LIC
Selection guide for LIP
Selection guide for LIF
Selection guide for LIDA
Selection guide for PP
Selection guide LIP/LIF/LIC (vacuum)
LIP 481V / LIP 481U
LIF 471V / LIF 481V
LIC 4113V / LIC 4193V
LIP/LIF series for application in high and ultrahigh vacuum technology
Typ
Basline error
Substrate and mounting
Interpolation error
Measuring length
Accuracy
grade
Interval
LIP 481V
LIP 481U
± 0.5 μm
± 1 μm
≤ ± 0.175 μm/ 5 mm
Scale of Zerodur glass ceramic or glass with fi
xing clamps
± 7 nm
70 mm to 420 mm
LIF 471V
LIF 481V
± 3 μm
≤ ± 0.225 μm/ 5 mm
± 12 nm
70 mm to 1640 mm
LIC 4113 V
LIC 4193 V
±1 µm (only for Robax glass ceramic), ±3 µm, ±5 µm
≤ ±0.275 µm/10 mm
METALLUR scale grating on glass ceramic or glass
± 20 nm
240 mm to 3040 mm
×