Transceiver
Radio and infrared
Infrared
SE 661
SE 660
SE 642
SE 540
Use with
TS 460 and TT 460;any number may be connected
TS 460 and TT 460;up to four each may be connected (depending on the variant)
TS 460, TS 642, TS 740, and TT 460
TS 460, TS 642, or TS 740
Signal transmission
Radio or infrared
Area of application
In working space of machine
In the mating bore
of the main spindle
Interface
Serial data (EnDat 2.2)
Square-wave signals (HTL)
Optical status indicator
For infrared transmission, radio transmission radio channel quality, channel, operating mode, and whether workpiece or tool touch probe
For infrared transmission, errors, and whether workpiece or tool touch probe
For touch probe
Electrical connection
8-pin M12 flange socket
12-pin M12 flange socket
Cable, 0.5 m/2 m with 12-pin M12 connector
8-pin M9 flange socket
Cable length
≤ 50 m
≤ 20 m with adapter cable ¬ 6 mm≤ 50 m with adapter cable ¬ 6 mm and adapter cable ¬ 8 mm for extension
≤ 30 m with adapter cable ¬ 4.5 mm≤ 50 m with adapter cable ¬ 4.5 mm and adapter cable ¬ 8 mm for extension
Supply voltage
DC 15 V to 30 V
Current consumption without load1)
Normal operation Transmission (max. 3.0 s)Radio
3.8 Weff (≤ 220 mAeff)12 WPK (≤ 755 mAPK)2.4 Weff (≤ 135 mAeff)
3.4 Weff (≤ 200 mAeff)10.7 WPK (≤ 680 mAPK)2.1 Weff (≤ 120 mAeff)
5.1 Weff (≤ 250 mAeff)8.3 WPK (≤ 550 mAPK)–
3.7 Weff (≤ 150 mAeff)4.3 WPK (≤ 210 mAPK)–
Protection EN 60529
IP68
Operating temperature
10 °C to 40 °C
10 °C to 60 °C
Storage temperature
–20 °C to 70 °C
Mass without cable
0.3 kg
0.2 kg
0.1 kg
* Please select when ordering
1) At minimum supply voltage
Touch Probes for Machine Tools
Mounting Instructions SE 660
Mounting Instructions SE 642
Mounting Instructions SE 540